The facility constructed at NMi VSL to realize the ITS-90 in the capsule standard platinum resistance thermometer range (CSPRT, 13.8033–273.16K) is presented. To demonstrate the performance of our facility, the results of a recent measurement campaign are reported, in which 3 NMi VSL CSPRTs were calibrated in the range 13.8–273.16K at all of the fixed points required by the ITS-90. The uncertainty of the calibration of the CSPRTs at each of the fixed points is evaluated in accordance with the most recent recommendations of the Consultative Committee for Thermometry and its Working Groups 1 and 3.
机译:介绍了由NMi VSL建造的用于在胶囊标准铂电阻温度计范围(CSPRT,13.8033-273.16K)中实现ITS-90的设施。为了证明我们设施的性能,报告了最近一次测量活动的结果,其中在ITS-90要求的所有固定点上,将3个NMi VSL CSPRT校准在13.8–273.16K范围内。根据温度测量咨询委员会及其第1和第3工作组的最新建议,评估在每个固定点进行CSPRT校准的不确定性。