首页> 外文期刊>International Journal of Thermophysics >ITS-90 Scale Realization on the New Radiation Thermometer Calibration Facility at NMi VSL
【24h】

ITS-90 Scale Realization on the New Radiation Thermometer Calibration Facility at NMi VSL

机译:NMi VSL在新型辐射温度计校准设备上实现ITS-90规模

获取原文
获取原文并翻译 | 示例
           

摘要

In the first half of 2005, Nederlands Meetinstituut Van Swinden Laboratorium B.V. (NMi VSL) redesigned their facilities for radiation thermometry in a new laboratory building and an opportunity arose to implement new measurement methods. The new facility is used for ITS-90 realization and dissemination in the temperature range from − 50 °C to 3,000 °C. A study was performed to compare a silver-point realization with a fixed-point blackbody radiator (FP-BBR) to a sodium heat-pipe blackbody radiator (HP-BBR) traceable via a HTSPRT to a contact thermometry silver point. It was found that the fixed-point realization transfer to the sodium heat pipe results in an uncertainty from 0.2 K to 2.4 K for the ITS-90 over the temperature range from 961.78 °C to 3,000 °C.
机译:在2005年上半年,荷兰尼德兰会议科学与技术学院(NMi VSL)重新设计了他们在新实验室中进行辐射测温的设施,并出现了实施新测量方法的机会。新设备用于ITS-90的实现和传播,温度范围为− 50°C至3,000°C。进行了一项研究,将定点黑体辐射器(FP-BBR)的银点实现与可通过HTSPRT追溯到接触测温银点的钠热管黑体辐射器(HP-BBR)进行比较。已发现,在961.78°C至3,000°C的温度范围内,对于ITS-90,定点实现转移至钠热管会导致0.2 K至2.4 K的不确定性。