【24h】

Exergy Analysis of Modified Solar Still

机译:改性太阳蒸馏器的火用分析

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A new design of solar still consist of flat plate solar collector, heat exchanger and cooling tower, was built and tested under Iraq weather at March. The still was tested under different mass flow rate of brackish water entering the flate plate solar collector, ranging from 0.01 to 0.015 kg/s. The volume flow rate of air through cooling tower was 0.0195 m~3/s. A full details of overall system as well as for system components exergy analysis were achieved. It was found that the maximum daily exergy efficiency of the still is less than 1%. While the maximum hourly exergy efficiency and maximum productivity for such combination were 3.46 kg/day and 1.6% , respectively, when the mass flow rate of brackish water was 0.013 kg/s.
机译:建造了一种新的太阳能仍然由平板太阳能收集器,热交换器和冷却塔组成的设计,并在3月的伊拉克天气下进行了测试。在进入平板太阳能集热器的微咸水的质量流量为0.01至0.015 kg / s的情况下,对蒸馏器进行了测试。通过冷却塔的空气体积流量为0.0195 m〜3 / s。实现了整个系统以及系统组件的火用分析的完整细节。发现仍然最大的每日火用效率低于1%。当微咸水的质量流量为0.013kg / s时,这种组合的最大小时火用效率和最大生产率分别为3.46kg /天和1.6%。