Experimental analysis of thermal performance of evacuated tube and flat-plate solar air collectors at different air flow rates

机译:真空管和平板式太阳能集热器在不同风量下的热性能实验分析

获取原文
获取原文并翻译 | 示例
           

摘要

The thermal performances of an evacuated tube collector (ETC) and flat-plate solar air collector (FPC) are experimentally investigated at different air flow rates. To investigate the performance of the ETC and FPC, experimental set-ups were fabricated. Air was used as a working fluid and tested at the same climatic conditions. The ETC had 15 evacuated tubes with a surface area of 1.66 m~2. The experimental set-up consisted of a header with a hollow pipe (square pipe) in the centre through which the air flowed. The flat-plate collector had a surface area of 1.35 m~2. The FPC had a black painted absorber sheet which divides the collector into two sections. The air flowed through the upper and the lower sections parallel to the collector to minimize the overall heat loss. The temperature of the outlet air depends on several factors along with the airflow rate and the intensity of the solar radiation. It was found that during the day at high flow rates, the efficiency of the ETC varies from 0.12 to 0.5, and for the flat plate it was from 0.29 to 0.68. The maximum temperature of the air was 56.7℃ for the ETC and 25.7℃ for the FPC.
机译:实验研究了真空管式集热器(ETC)和平板式太阳能集热器(FPC)在不同空气流量下的热性能。为了研究ETC和FPC的性能,制作了实验装置。空气用作工作流体,并在相同的气候条件下进行了测试。 ETC有15个真空管,表面积为1.66 m〜2。实验装置包括一个集管,该集管的中央有一个空心管(方管),空气从中流过。平板收集器的表面积为1.35m〜2。 FPC有一个黑色的吸收板,将收集器分为两部分。空气流经平行于集热器的上部和下部,以使总热量损失最小。出口空气的温度取决于几个因素以及气流速度和太阳辐射的强度。发现在高流量的一天中,ETC的效率从0.12到0.5不等,而平板的ETC的效率从0.29到0.68。 ETC的最高空气温度为56.7℃,FPC的最高温度为25.7℃。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号