Partial penetration butt welded joints are widely used because they require relatively less weld metal for fabrication. However, incomplete penetration acts as a crack-like flaw. When the size of flaw in a material is known, the tensile strength of the material can be evaluated using fracture mechanics. This paper deals with a practical method of estimating the size of flaw (the incomplete penetration of a partial penetration butt welded joint) by ultrasonic testing (UT). The refraction angle of the probe and the method of UT are discussed. In addition, tensile strengths of welded joints are evaluated using fracture mechanics, and are found to be in good agreement with experimental results.
机译:部分渗透对接焊接接头被广泛使用,因为它们在制造时需要相对较少的焊接金属。但是,不完全的渗透会产生类似裂纹的缺陷。当已知材料中缺陷的大小时,可以使用断裂力学评估材料的拉伸强度。本文探讨了一种实用的方法,可通过超声测试(UT)估算缺陷的大小(部分渗透对接焊缝的不完全渗透)。讨论了探头的折射角和UT方法。另外,使用断裂力学评估了焊接接头的拉伸强度,并且发现其与实验结果非常吻合。