Recent power system events have shown that voltage collapse can be a root cause of some widespread outages. The thrust of this paper is to discuss some means of mitigating system voltage depressions that are available through the scheme which utilizes both Reactive Current droop Compensation (RCC) and Line Drop Compensation (LDC). The point that the voltage regulator controls can be acquired by a new method which is based on a widely accepted voltage stability analysis tool. This tool can determine which generators will have an impact on the maximum permissible loading of a bus and which will not. The dynamic analyses were carried out on the CIGRE Nordic test system to study the impact of control point location on time to collapse and prove that the new scheme can improve the voltage stability.
机译:最近的电力系统事件表明,电压崩溃可能是造成某些广泛停机的根本原因。本文的重点是讨论一些缓解系统压降的方法,这些方法可通过利用无功电流压降补偿(RCC)和线路压降补偿(LDC)的方案获得。可以通过一种基于广泛接受的电压稳定性分析工具的新方法来获得电压调节器控制的要点。该工具可以确定哪些发电机会对母线的最大允许负载产生影响,而哪些不会。在CIGRE Nordic测试系统上进行了动态分析,研究了控制点位置对崩溃时间的影响,并证明了新方案可以提高电压稳定性。