Power flow analysis is of great importance in planning and designing for the future expansion of power systems as well as in determining the best operation of existing systems. Although the standard Newton-Raphson (NR) method is the most powerful algorithm for the power flow analysis in electric power systems, the calculation of jacobian matrix derivatives involves high computational time. This paper presents a simplified NR power flow solution method to simplify overall equation complexity and computation time. The simplified NR method employs nonlinear current mismatch equations instead of the commonly used power mismatch equations. Numerical results are carried out on a standard 5-bus test system, IEEE 30-bus test system and IEEE 57-bus test system. The results of standard NR method and simplified NR method are compared in terms of bus voltages, total system losses, computation time and convergence characteristics to show the effectiveness of simplified NR method.
机译:潮流分析对于规划和设计电力系统的未来扩展以及确定现有系统的最佳运行至关重要。尽管标准牛顿-拉夫森(NR)方法是电力系统中潮流分析的最强大算法,但是雅可比矩阵导数的计算需要大量的计算时间。本文提出了一种简化的NR潮流解决方案方法,以简化整体方程的复杂性和计算时间。简化的NR方法采用非线性电流失配方程,而不是常用的功率失配方程。数值结果在标准的5总线测试系统,IEEE 30总线测试系统和IEEE 57总线测试系统上进行。从母线电压,系统总损耗,计算时间和收敛特性等方面对标准降噪法和简化降噪法的结果进行了比较,证明了简化降噪法的有效性。