Groundwater can be contaminated when e.g. gasoline tanks leak. Due to sampling and lab analysis, groundwater monitoring is time consuming and expensive. The technologies developed for rapid on-site analysis of gasoline contaminated groundwater face the technical limitation to distinguish the gasoline from complex matrices. In the present study the fingerprint identification of volatile organic components (VOCs) in gasoline contaminated groundwater using gas chromatography (GC) differential ion mobility spectrometry (DMS) is investigated. Groundwater was spiked with five sorts of gasoline (one reformulated gasoline, gasoline without additives and three different brand gasoline collected on petrol stations) and analyzed by GC-DMS. Seven VOCs (benzene, toluene, ethyl benzene, m-xylene, p-xylene, o-xylene, 1,2,4-trimethylbenzene) were identified by GC mass spectrometry (GC-MS) as well as by GC-DMS and selected as markers. The semi-quantitative determination of the selected compounds was achieved. The limits of detection of the GC-DMS are 46.42 ng for benzene, 1.13 ng for toluene, 1.80 ng for ethylbenzene, 0.22 ng for m-xylene, 1.13 ng for p-xylene, 0.61 ng for o-xylene and 0.37 ng for 1,2,4-trimethylbenzene, respectively. These results reveal the feasibility of GC-DMS for on-site monitoring of contaminated groundwater.
机译:地下水可能在例如汽油箱泄漏。由于采样和实验室分析,地下水监测既费时又昂贵。快速现场分析汽油污染的地下水所开发的技术面临着将汽油与复杂基质区分开的技术限制。在本研究中,使用气相色谱(GC)差分离子迁移谱法(DMS)进行了指纹识别汽油污染的地下水中挥发性有机成分(VOC)的研究。用五种汽油(一种经重新配制的汽油,无添加剂的汽油和从加油站收集的三种不同品牌的汽油)掺入地下水,并通过GC-DMS进行分析。通过GC质谱(GC-MS)和GC-DMS鉴定了7种VOC(苯,甲苯,乙苯,间二甲苯,对二甲苯,邻二甲苯,1,2,4-三甲基苯),并进行了选择作为标记。实现了所选化合物的半定量测定。 GC-DMS的检出限为苯为46.42 ng,甲苯为1.13 ng,乙苯为1.80 ng,间二甲苯为0.22 ng,对二甲苯为1.13 ng,邻二甲苯为0.61 ng,1为0.37 ng ,2,4-三甲基苯。这些结果表明,GC-DMS可用于现场监测受污染的地下水。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号