Verification of the efficiency of chemical disinfection and sanitation measures in in-building distribution systems

机译:验证室内分配系统中化学消毒和卫生措施的效率

获取原文
获取原文并翻译 | 示例
           

摘要

Previous investigations of biofilms, generated in a silicone tube model have shown that the number of colony forming units (CFU) can reach 10~7/cm~2, the total cell count (TCC) of microorganisms can be up to 10~8 cells/cm~2.rnThe present study focuses on the situation in in-building distribution systems. Different chemical disinfectants were tested for their efficacy on drinking water biofilms in silicone tubes: free chlorine (electrochemically activated), chlorine dioxide, hydrogen peroxide (H_2O_2), silver, and fruit acids.rnWith regard to the widely differing manufacturers' instructions for the usage of their disinfectants three different variations of the silicone tube model were developed to simulate practical use conditions..rnFirst the continuous treatment, second the intermittent treatment, third the efficacy of external disinfection treatment and the monitoring for possible biofilm formation with the Hygiene-Monitor. The working experience showed that it is important to know how to handle the individual disinfectants. Every active ingredient has its own optimal application concerning its concentration, exposure time, physical parameters like pH, temperature or redox potential. When used correctly all products tested were able to reduce the CFU to a value below the detection limit. Most of the active ingredients could not significantly reduce the TCC/cm~2, which means that viable microorganisms may still be present in the system. Thus the question arises what happened with these cells? In some cases SEM pictures of the biofilm matrix after a successful disinfection still showed biofilm residues. According to these results, no general correlation between CFU/cm~2, TCC/cm~2 and the visualised biofilm matrix on the silicone tube surface (SEM) could be demonstrated after a treatment with disinfectants.
机译:先前对硅胶管模型产生的生物膜的研究表明,菌落形成单位(CFU)的数量可以达到10〜7 / cm〜2,微生物的总细胞数(TCC)可以达到10〜8个细胞/cm~2.rn目前的研究集中在室内分配系统中。测试了不同化学消毒剂对有机硅管中饮用水生物膜的功效:游离氯(电化学活化),二氧化氯,过氧化氢(H_2O_2),银和果酸。rn关于制造商使用说明的差异很大他们的消毒剂开发了三种不同的硅胶管模型来模拟实际使用条件。首先,进行连续处理,其次是间歇处理,其次是外部消毒处理的功效,并通过卫生监测仪监测可能的生物膜形成。工作经验表明,了解如何处理各个消毒剂非常重要。每种活性成分在其浓度,暴露时间,物理参数(例如pH,温度或氧化还原电位)方面都有自己的最佳应用。如果正确使用,所有测试的产品都能够将CFU降低到低于检测极限的值。大多数活性成分不能显着降低TCC / cm〜2,这意味着该系统中仍可能存在活菌。因此,问题来了,这些细胞发生了什么?在某些情况下,成功消毒后生物膜基质的SEM照片仍显示出生物膜残留物。根据这些结果,用消毒剂处理后,在CFU / cm〜2,TCC / cm〜2与硅胶管表面(SEM)上可视化的生物膜基质之间没有普遍的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号