首页> 外文期刊>International journal of hydrogen energy >Tests on LmNi_(4.91)Sn_(0.15) based solid state hydrogen storage device with embedded cooling tubes - Part A: Absorption process
【24h】

Tests on LmNi_(4.91)Sn_(0.15) based solid state hydrogen storage device with embedded cooling tubes - Part A: Absorption process

机译:具有嵌入式冷却管的基于LmNi_(4.91)Sn_(0.15)的固态储氢装置的测试-A部分:吸收过程

获取原文
获取原文并翻译 | 示例
           

摘要

In Part A of this manuscript which consists of two parts, the experimental investigations pertaining to the absorption of hydrogen in an LmNi_(4.91)Sn_(0.15) based solid state hydrogen storage device with embedded cooling tubes (ECT) are presented. Two metal hydride based hydrogen storage devices with 36 and 60 ECT filled with 2.75 kg of LmNi_(4.91)Sn_(0.15) were fabricated. Performances of the hydrogen storage devices in terms of hydrogen absorption rate and amount of hydrogen absorbed are reported for different supply pressures (10 -35 bar), absorption temperatures (20-30 ℃) and cooling fluid flow rates (2.2-30 l/min). At any given absorption temperature, the rate of hydrogen absorption and the amount of hydrogen absorbed are found to increase with hydrogen supply pressure up to about 35 bar. At the supply condition of 35 bar hydrogen pressure and 30 ℃ absorption temperature, with oil as a heat transfer fluid at a flow rate of 3.2 l/min, the maximum amount of hydrogen absorbed are ≈1.18 wt% in 10 min for 36 ECT, and 8 min for 60 ECT. At the absorption condition of 25 bar supply pressure, 30 l/min water flow rate and 30 ℃ absorption temperature, the absorption time of the reactor with 60 ECT was reduced to 5 min.
机译:在由两部分组成的手稿的A部分中,进行了有关在带有嵌入式冷却管(ECT)的LmNi_(4.91)Sn_(0.15)基固态储氢装置中吸收氢的实验研究。制备了两个金属氢化物基储氢装置,其分别装有36和60 ECT并填充了2.75 kg LmNi_(4.91)Sn_(0.15)。报告了在不同的供气压力(10 -35 bar),吸收温度(20-30℃)和冷却液流量(2.2-30 l / min)下,储氢装置在吸氢率和吸氢量方面的性能。 )。在任何给定的吸收温度下,发现氢吸收速率和氢吸收量随氢供应压力增加至约35 bar而增加。在35 bar氢气压力和30℃吸收温度的供应条件下,以油作为传热流体,流速为3.2 l / min,36 ECT的最大吸收氢量在10分钟内约为1.18 wt%, 60 ECT则需要8分钟。在25 bar的供应压力,30 l / min的水流量和30℃的吸收温度的吸收条件下,采用60 ECT的反应器的吸收时间减少到5 min。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号