首页> 外文期刊>International Journal of Heat and Mass Transfer >Condensation heat transfer and pressure drop of refrigerant R-410A flow in a vertical plate heat exchanger
【24h】

Condensation heat transfer and pressure drop of refrigerant R-410A flow in a vertical plate heat exchanger

机译:制冷剂R-410A在垂直板式热交换器中的冷凝传热和压降

获取原文
获取原文并翻译 | 示例
       

摘要

Heat transfer and associated frictional pressure drop in the condensing flow of the ozone friendly refrigerant R-410A in a vertical plate heat exchanger (PHE) are investigated experimentally in the present study. In the experiment two vertical counter flow channels are formed in the exchanger by three plates of commercial geometry with a corrugated sinusoidal shape of a chevron angle of 60°. Downflow of the condensing refrigerant R-410A in one channel releases heat to the upflow of cold water in the other channel. The effects of the refrigerant mass flux, imposed heat flux, system pressure (saturated temperature) and mean vapor quality of R-410A on the measured data are explored in detail. The results indicate that the R-410A condensation heat transfer coefficient and associated frictional pressure drop in the PHE increase almost linearly with the mean vapor quality, but the system pressure only exhibits rather slight effects. Furthermore, increases in the refrigerant mass flux and imposed heat flux result in better condensation heat transfer accompanying with a larger frictional pressure drop. Besides, the imposed heat flux exhibits stronger effects on the heat transfer coefficient and pressure drop than the refrigerant mass flux especially at low refrigerant vapor quality. The friction factor is found to be strongly influenced by the refrigerant mass flux and vapor quality, but is almost independent of the imposed heat flux and saturated pressure. Finally, an empirical correlation for the R-410A condensation heat transfer coefficient in the PHE is proposed. In addition, results for the friction factor are correlated against the Boiling number and equivalent Reynolds number of the two-phase condensing flow.
机译:在本研究中,通过实验研究了垂直板式换热器(PHE)中的臭氧友好制冷剂R-410A的冷凝流中的传热和相关的摩擦压降。在实验中,两个垂直的逆流通道由三块商业化的几何形状的板形成,它们的波形呈正弦波状,人字形角度为60°。一个通道中的冷凝制冷剂R-410A的向下流动将热量释放给另一通道中的冷水上升。详细探讨了制冷剂质量通量,施加的热通量,系统压力(饱和温度)和R-410A的平均蒸汽质量对测量数据的影响。结果表明,P-HE中的R-410A冷凝传热系数和相关的摩擦压降与平均蒸气质量几乎呈线性增加,但是系统压力仅表现出较小的影响。此外,制冷剂质量通量的增加和施加的热通量导致更好的冷凝热传递,并伴随较大的摩擦压降。此外,施加的热通量比制冷剂质量通量对传热系数和压降表现出更大的影响,特别是在低制冷剂蒸汽质量下。已发现摩擦系数受制冷剂质量通量和蒸汽质量的强烈影响,但几乎与施加的热通量和饱和压力无关。最后,提出了PHE中R-410A冷凝传热系数的经验关系式。另外,摩擦因数的结果与两相冷凝流的沸腾数和等效雷诺数相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号