首页> 外文期刊>International Journal of Heat and Mass Transfer >Local wall heat flux in confined thermal convection
【24h】

Local wall heat flux in confined thermal convection

机译:有限热对流中的局部壁热通量

获取原文
获取原文并翻译 | 示例
       

摘要

We report highly resolved measurements of the local wall heat flux in turbulent Rayleigh-Benard convection using an infrared camera. The measurements have been undertaken in a Rayleigh-Benard cell with rectangular base of 2.50 m × 0.65 m and a height of 2.5 m which is filled with air. First of all, it could be demonstrated that in a Rayleigh-Benard cell with rectangular cross-section the time-averaged wall heat flux locally deviates by 30% from its mean. Furthermore, a strong correlation between the global flow structure inside the cell and the distribution of the local wall heat flux could be identified.
机译:我们报告了使用红外热像仪对湍流瑞利-贝纳德对流中局部壁热通量的高度分辨的测量结果。测量是在具有2.50 m×0.65 m矩形底部和2.5 m高度并充满空气的Rayleigh-Benard单元中进行的。首先,可以证明,在具有矩形横截面的Rayleigh-Benard单元中,时间平均壁热通量局部偏离其平均值30%。此外,可以确定单元内部的整体流动结构与局部壁热通量的分布之间有很强的相关性。