Heat transfer of in-tube supercritical fluid cooling accompanying out-tube pool boiling was investigated. A smooth horizontal circular tube with an inside-diameter of 20 mm was submerged in a water pool at atmospheric pressure. Test parameters of in-tube were as follows: Pressure: 23-28 MPa, mass flux: 600-1000 kg.m(-2).s(-1), fluid temperature: 400-725 K, and the temperature difference between bulk and wall: 300-374 K. A thermal amplification system based on out-tube pool boiling was used to improve the measurement accuracy of local heat duty near pseudocritical region. According to the experiment, the transition from nucleate boiling to film boiling in the pool occurred near the pseudo-critical fluid region. Sharp variation on thermo-physical properties led to the peak value of heat transfer coefficient in the pseudo-critical region. The pool boiling heat flux increased gradually to 1.19 MWm(-2) near the pseudo critical point. Based on the experimental data, a modified Gnielinski equation was adopted to predict the heat transfer coefficient of in-tube supercritical fluid cooling with out-tube pool boiling. The thermophysical property ratio of the wall to the bulk as well as the effect of buoyancy were taken into consideration in the new correlation. The predicted correlation has an error of less than 20% to the experimental data. (C) 2019 Elsevier Ltd. All rights reserved.
机译:研究了伴随管外池沸腾的管内超临界流体冷却的传热。将内径为20 mm的光滑水平圆形管浸没在大气压下的水池中。管内的测试参数如下:压力:23-28 MPa,质量通量:600-1000 kg.m(-2).s(-1),流体温度:400-725 K,两者之间的温差体积和壁厚:300-374K。基于管外池沸腾的热放大系统用于提高伪临界区附近局部热负荷的测量精度。根据实验,池中从核沸腾到膜沸腾的转变发生在伪临界流体区域附近。热物理性质的急剧变化导致伪临界区的传热系数达到峰值。在伪临界点附近,池沸腾热通量逐渐增加至1.19 MWm(-2)。根据实验数据,采用修正的Gnielinski方程来预测管内超临界流体在管外池沸腾中的传热系数。在新的关联中考虑了壁与主体的热物理性质比以及浮力的影响。预测的相关性与实验数据的误差小于20%。 (C)2019 Elsevier Ltd.保留所有权利。

著录项

  • 来源
  • 作者单位

    China Ship Dev & Design Ctr, Wuhan, Hubei, Peoples R China|Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China;

    Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China;

    Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China;

    Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China;

    Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Supercritical water; Heat transfer; Cooling with pool boiling; Thermal amplification;