A new method has been developed for the preconcentration of trace amounts of manganese and cadmium prior to their determination by flame atomic absorption spectrometry (FAAS). The method is based on using a microcolumn packed with 1-(2-pyridylazo)-2-naphthol (PAN)-modified sodium dodecyl sulfate (SDS) coated TiO_2 nanoparticles as a solid-phase sorbent. Effects of pH, sample flow rate and volume, elution solution and interfering ions on the recovery of the analytes have been investigated. The adsorption capacity of modified TiO_2 nanoparticles was found to be 9.2 and 8.9 mg g~(-1) for Mn and Cd, respectively. The detection limits (3σ) of this method are 1.0 and 0.96 ng mL~(-1) for Mn and Cd, respectively. The proposed method has been applied to the determination of the elements in water samples with satisfactory results.
机译:已经开发了一种新方法,用于通过火焰原子吸收光谱法(FAAS)测定痕量锰和镉。该方法基于使用填充有1-(2-吡啶基偶氮)-2-萘酚(PAN)改性十二烷基硫酸钠(SDS)涂层的TiO_2纳米颗粒的微柱作为固相吸附剂。研究了pH,样品流速和体积,洗脱液和干扰离子对分析物回收率的影响。改性后的TiO_2纳米颗粒对Mn和Cd的吸附量分别为9.2和8.9 mg g〜(-1)。该方法的检出限(3σ)对Mn和Cd分别为1.0和0.96 ng mL〜(-1)。该方法已用于水样中元素的测定,结果令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号