首页> 外文期刊>International Journal of Electrical Power & Energy Systems >Phase shifting transformer model for direct approach power flow studies
【24h】

Phase shifting transformer model for direct approach power flow studies

机译:用于直接进场潮流研究的相移变压器模型

获取原文
获取原文并翻译 | 示例
           

摘要

This proposal is intended to extend the field of application of an extremely efficient power flow algorithm used in radial and weakly meshed grids, the so-called Direct Approach (DA) method. In this work the method is broadened with the possibility of handling shunt admittances, transformers with taps, and phase shifting transformers. While the integration of the two former elements in the DA solver is quite straightforward, the use of phase shifting transformers is far from obvious due to their inherent non symmetrical admittance matrix. Thus, a model for phase shifting transformers is proposed in this contribution, which allows the use of the DA method in grids that include such devices. A set of case studies is conducted in the contexts of a balanced industrial grid and a standard testbed to demonstrate the validity of the proposal. (C) 2017 The Authors. Published by Elsevier Ltd.
机译:该提议旨在扩展一种用于径向和弱网格的极有效功率流算法的应用领域,即所谓的直接方法(DA)方法。在这项工作中,该方法拓宽了处理并联导纳,带有抽头的变压器和移相变压器的可能性。虽然DA求解器中前两个元素的集成非常简单,但由于其固有的非对称导纳矩阵,因此移相变压器的使用远非显而易见。因此,在该贡献中提出了用于相移变压器的模型,该模型允许在包括这种设备的电网中使用DA方法。在平衡的工业网格和标准测试平台的背景下进行了一组案例研究,以证明该建议的有效性。 (C)2017作者。由Elsevier Ltd.发布