As smart grid applications, distributed generation, and microgrid technologies have become more widespread, new safety-related issues have arisen. Unintentional islanding is an example of a grid fault that may result in damage to electrical equipment and severe personal injuries. In this paper, an anti-islanding system employing power line communication (PLC) and direct-sequence spread spectrum (DSSS) modulation implemented with software-defined radios for continuous signaling is tested in a laboratory test setup. A concept of a fault detection algorithm is evaluated. A DSSS sensitivity analysis is carried out to investigate system's performance against variation of a signal-to-noise ratio, and define optimal DSSS settings. The results of the analysis are interpreted, and conclusions are drawn. A transformer bypassing scheme allowing to increase the fault detection speed and throughput is introduced and tested, and the conditions of applicability are described. As a result of the study, recommendations for the system development are presented.
机译:随着智能电网应用,分布式发电和微电网技术变得越来越普遍,出现了新的与安全相关的问题。无意孤岛是电网故障的一个例子,可能导致电气设备损坏和严重的人身伤害。在本文中,在实验室测试设置中测试了采用电力线通信(PLC)和直接序列扩频(DSSS)调制并结合软件定义的无线电实现连续信令的防孤岛系统。评估了故障检测算法的概念。进行了DSSS灵敏度分析,以研究系统性能对信噪比变化的影响,并定义最佳DSSS设置。分析结果得到解释,并得出结论。介绍并测试了允许提高故障检测速度和吞吐量的变压器旁路方案,并描述了适用条件。作为研究的结果,提出了有关系统开发的建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号