The incomplete knowledge of the power distribution grid status and in particular the impossibility to constantly monitor the number of subjects (feeder) able to inject current autonomously at a known time can represent a hazardous condition for the main utility provider operators' safety. Whenever an unexpected islanding condition is induced on the utility grid, every subject injecting power on the grid should stop such injection switching to a safety shut down condition. Due to the presence of multi injecting sources on the utility grid it is possible that one or more feeders do not recognise such event and continue to supply energy to a portion of the utility grid, keeping the main provider operators unaware of such condition. Such situation is the islanding condition. The present work aims, starting from a previous paper Fort et al. (2010) at assessing the robustness of an anti-islanding detection system in presence of a uniform distributed noise sources on the grid. The anti islanding detection system is based on the injection of an interharmonic component on the grid. The single phase case is considered. In this paper it is considered the optimum tradeoff between the harmonic distortion injection of a component which is required to be both meaningful from a signal to noise ratio standpoint and low enough not to affect the overall grid THD. The aim of this paper is to prove that such device will constitute a low cost, stand alone, and reliable automatic detection system for grid disconnection detection, to be supplied in conjunction with devices like the photovoltaic (PV) inverters in order to minimise their islanding non-detection zone.
机译:对配电网状态的不完全了解,尤其是无法持续监控能够在已知时间自动注入电流的受检者(馈线)的数量,可能对主要公用事业运营商的安全构成危险。每当在公用电网上引发意外的孤岛状态时,电网上的每个对象注入功率都应停止将这种注入切换到安全关闭状态。由于公用电网上存在多个注入源,有可能一个或多个馈线无法识别此类事件,并继续向公用电网的一部分供电,从而使主要供应商的运营商不了解这种情况。这种情况就是孤岛状况。本工作的目标是从上一篇Fort等人的论文开始。 (2010年)在电网上存在均匀分布的噪声源的情况下评估反孤岛检测系统的鲁棒性。防孤岛检测系统基于在电网上注入间谐波分量。考虑单相情况。在本文中,考虑了从信号噪声比的观点出发既有意义又要低到不影响整个电网THD的分量的谐波失真注入之间的最佳权衡。本文的目的是证明这种设备将构成一种低成本,独立且可靠的用于电网断开检测的自动检测系统,与诸如光伏(PV)逆变器之类的设备一起提供,以最大程度地减少其孤岛非检测区。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号