首页> 外文期刊>The International Journal of Cardiovascular Imaging >Relationship between beat to beat coronary artery motion and image quality in prospectively ECG-gated two heart beat 320-detector row coronary CT angiography
【24h】

Relationship between beat to beat coronary artery motion and image quality in prospectively ECG-gated two heart beat 320-detector row coronary CT angiography

机译:心电门控两次心跳320探测器行冠状动脉CT血管成像中搏动搏动冠状动脉运动与图像质量之间的关系

获取原文
获取原文并翻译 | 示例
       

摘要

The objective was to investigate the influence of the beat-to-beat movement of the coronary arteries on image quality of multi-segment reconstruction (MSR) images. Although MSR improves temporal resolution, image quality would be degraded by beat-to-beat movement of the coronary arteries. In a retrospectively review, 18 patients (mean age, 67.0 years) who underwent coronary CT angiography using a 320-detector row CT were included. The displacement and diameter of coronary artery segments for each of the identified nine landmarks was recorded. The motion ratio was calculated as the division of displacement by diameter. Image quality (IQ) was graded by a four-point scale. The correlation between MSR IQ score and the motion ratio showed stronger negative correlation than that between MSR IQ score and the displacement (r = ?0.54 vs. r = ?0.36). The average motion ratio for segments in which half-scan reconstruction (HSR) IQ was better than MSR IQ (29.1%, group A) was higher than that for segments in which MSR IQ was better than HSR IQ (16.0%, group C). The motion ratio in group C was lower than 25%. Difference in IQ scores of the HSR images was more frequent in group A than in the remaining segments in which the motion ratio was lower than 25% (16.7% vs. 66.0%; P < 0.0002). The motion ratio could be a better index than the displacement to evaluate the influence of the motion of coronary arteries on image quality. MSR images would be impaired by a motion ratio larger than 25%. Image impairment of one of the HSR images might also impair MSR images.
机译:目的是研究冠状动脉的逐搏运动对多节段重建(MSR)图像的图像质量的影响。尽管MSR改善了时间分辨率,但由于冠状动脉的逐次运动,图像质量会下降。在一项回顾性审查中,纳入了18例患者(平均年龄67.0岁),他们使用320排行CT进行了冠脉CT血管造影。记录每个确定的九个标志的冠状动脉节段的位移和直径。将运动比计算为位移除以直径。图像质量(IQ)由四分制评分。 MSR IQ得分与运动比之间的相关性显示出比MSR IQ得分与位移之间的负相关性更强的负相关性(r =?0.54 vs. r =?0.36)。半扫描重建(HSR)IQ优于MSR IQ的段的平均运动比(29.1%,A组)高于MSR IQ优于HSR IQ的段的平均运动比(16.0%,C组) 。 C组的运动率低于25%。与运动率低于25%的其余部分相比,A组中HSR图像的IQ得分差异更为频繁(16.7%对66.0%; P <0.0002)。运动比可能是比位移更好的指标,以评估冠状动脉运动对图像质量的影响。大于25%的运动比会损害MSR图像。 HSR图像之一的图像损伤也可能损害MSR图像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号