An integrated simulation model is developed to investigate the steady-state and dynamic performance of multi-unit air conditioners (MUACs). It is built as two-phase fluid network which is able to describe different systems by incidence matrixes. And the submodels are embedded in the system framework, where the submodels can be either steady-state or dynamic model, distributed parameter or lumped parameter model. For this case, the numerical submodels are employed with moving-boundary models of condenser and evaporator, steady-state models of compressor and electronic expansion valve. The comparison with experimental data shows that it cannot only predict the steady-state performance, but also catch dynamic trends with high accuracy, for example, the differences of evaporating pressure < ±4%, condensing pressure < ±3%, compressor discharge temperature < ±4℃, superheating degree < ±2℃ and subcooling degree < ± 1℃. Therefore, the simulation model is confirmed as an effective tool to analyze the steady and transient characteristics and optimize the design and control algorithm of MUACs.
机译:开发了一个集成的仿真模型来研究多单元空调(MUAC)的稳态和动态性能。它被构建为两相流体网络,能够通过入射矩阵描述不同的系统。并将子模型嵌入系统框架中,其中子模型可以是稳态模型或动态模型,分布式参数或集总参数模型。对于这种情况,将数值子模型与冷凝器和蒸发器的移动边界模型,压缩机和电子膨胀阀的稳态模型一起使用。与实验数据的比较表明,它不仅可以预测稳态性能,而且还可以捕获高精度的动态趋势,例如,蒸发压力之差<±4%,冷凝压力之差<±3%,压缩机排气温度< ±4℃,过热度<±2℃,过冷度<±1℃。因此,该仿真模型被认为是分析MUAC稳态和暂态特性并优化MUAC设计和控制算法的有效工具。

著录项

  • 来源
    《International journal of air-conditioning and refrigeration》 |2012年第4期|1250020.1-1250020.9|共9页
  • 作者单位

    Technical Institute of Physics and Chemistry Chinese Academy of Sciences No.29 Zhongguancun East Road Haidian District, Beijing 100190, P. R. China;

    Technical Institute of Physics and Chemistry Chinese Academy of Sciences No.29 Zhongguancun East Road Haidian District, Beijing 100190, P. R. China;

    Technical Institute of Physics and Chemistry Chinese Academy of Sciences No.29 Zhongguancun East Road Haidian District, Beijing 100190, P. R. China;

    Technical Institute of Physics and Chemistry Chinese Academy of Sciences No.29 Zhongguancun East Road Haidian District, Beijing 100190, P. R. China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    heat pump; air conditioner; simulation; transient state; variable speed;

    机译:热泵;冷气机;模拟;瞬态变速;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号