R-404A, which had long been used as the refrigerant of a unitary ice maker, has to be replaced due to global warming. In the present study, drop-in tests were conducted for long-term alternative refrigerants R-455A and R-454C on the ice maker of 100 kg/day capacity. Five samples were made having different combinations of refrigerant, condenser and compressor. Tests were conducted changing the outdoor and the supply water temperature. At the standard outdoor condition (21℃, 65 RH and 10℃ water temperature), change of refrigerant from R-404A to R-455A for the same ice maker extended the ice ball formation time by 13% and reduced the amount of ice production per day by 6%. Larger vapor density and smaller temperature glide of R-404A may have resulted in a better performance. Furthermore, adoption of a larger (from 1/3 HP to 3/8 HP) compressor reduced the ice ball formation time by 12% and increased the amount of ice production per day by 8%. In addition, change of the fin-tube condenser to the microchannel condenser reduced the ice ball formation time by 9% and increased the amount of ice production per day by 4%. The refrigerant charge was also significantly reduced from 440 g to 316 g. Thermal performance of R-454C was poorer than that of R-455A. Replacement to R-454C increased the ice ball formation time by 14% and decreased the amount of ice production per day by 8%. The reason may be attributed to a larger pressure lift, which leads to smaller refrigerant mass flow rate. Ice production was possible even at the harsh environment (35℃, 65 RH and 21℃ water temperature), although the production amount decreased.
机译:长期以来一直用作整体制冰机制冷剂的R-404A,由于全球变暖而必须更换。在本研究中,对制冰机的每日替代能力为100 kg / day的长期替代制冷剂R-455A和R-454C进行了直接测试。制成了五个样品,它们具有制冷剂,冷凝器和压缩机的不同组合。进行了改变室外温度和供水温度的测试。在标准室外条件(21℃,65 RH和10℃水温)下,同一制冰机将制冷剂从R-404A更改为R-455A可以将冰球形成时间延长13%,并减少了制冰量每天增加6%。 R-404A的较大蒸汽密度和较小的温度滑动可能会导致更好的性能。此外,采用更大的压缩机(从1/3 HP到3/8 HP)可将冰球形成时间减少12%,并将每天的制冰量增加8%。另外,将翅片管冷凝器更换为微通道冷凝器可将冰球形成时间减少9%,并将每天的制冰量增加4%。制冷剂充注量也从440 g显着减少到316 g。 R-454C的热性能比R-455A差。替换为R-454C可将冰球形成时间增加14%,并将每天的制冰量减少8%。原因可能归因于较大的压力升程,这导致较小的制冷剂质量流量。尽管产量减少,但即使在恶劣的环境(35℃,65 RH和21℃的水温)下也可以制冰。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号