Toward mapping spatiotemporal characteristics of muscle oxygenation in different motor modalities by multichannel near-infrared spectroscopy

机译:通过多通道近红外光谱法在不同电动机模型中映射肌氧的肌肉氧合的时空特征

获取原文
获取原文并翻译 | 示例
       

摘要

Commonly, the near-infrared spectroscopy (NIRS) devices are used to measure muscle oxygenated hemoglobin (HBO) concentration and total hemoglobin (HBT) concentration with a single channel, which can obtain the temporal HBO and HBT signals. Lacking of the spatial information of muscle oxygenation will limit the exploration of the heterogeneity of muscle activities. In this study, a multichannel NIRS recording system was used to measure the muscle oxygenation with an attempt to simultaneously provide the temporal and spatial HBO and HBT concentration. In the experiment, the influences of four motor tasks, including active, passive, imaginary movement, and the control task (no movement), on muscle oxygenation were investigated in eight normal subjects. Our results showed that both amplitude and spatial heterogeneity associated with variation in muscle oxygenation during active and passive motor tasks were significantly different between the motor time and rest time (P 0.05). Furthermore, the region where HBO concentration decreased during the active motor task was in accordance with the anatomical position of contracted muscle, which cannot be observed from the results of the passive task. Considering the imaginary and control tasks in which the muscle was in a fixed/stationary state, the amplitude and spatial heterogeneity associated with variations in muscle oxygenation only exhibited slight changes (P 0.05). This pilot study suggested that the spatiotemporal information obtained from multichannel NIRS devices might be potential for accurate measurement of the variation in muscle oxygenation during motor tasks, which would be useful for different clinical applications.
机译:通常,近红外光谱(NIRS)器件用于测量肌肉含氧血红蛋白(HBO)浓度和总血红蛋白(HBT)浓度,单个通道可以获得颞型HBO和HBT信号。缺乏肌肉氧合的空间信息将限制肌肉活动的异质性的探索。在该研究中,使用多通道NIRS记录系统来测量肌肉氧合,试图同时提供时间和空间HBO和HBT浓度。在实验中,在八个正常受试者中研究了四种电动机任务的影响,包括有效,被动,虚部的运动和控制任务(无运动),在肌肉氧合上。我们的研究结果表明,电动机时间和休息时间之间有效和无源电动机任务中的肌肉氧气变化的幅度和空间异质性在显着差异(P <0.05)。此外,在活性电机任务期间降低的区域的区域符合收缩肌肉的解剖位置,这不能从被动任务的结果中观察到。考虑到肌肉处于固定/固定状态的假想和控制任务,与肌肉氧合的变化相关的幅度和空间异质性仅表现出微小的变化(P> 0.05)。该试点研究表明,从多通道NIRS设备获得的时空信息可能是精确测量电动机任务期间肌肉氧气变化的可能性,这对于不同的临床应用是有用的。

著录项

  • 来源
  • 作者单位

    Chinese Acad Sci Shenzhen Inst Adv Technol CAS Key Lab Human Machine Intelligence Synergy Sy Shenzhen 518055 Peoples R China|Univ Chinese Acad Sci Shenzhen Coll Adv Technol Shenzhen Peoples R China;

    Chinese Acad Sci Shenzhen Inst Adv Technol CAS Key Lab Human Machine Intelligence Synergy Sy Shenzhen 518055 Peoples R China;

    Chinese Acad Sci Shenzhen Inst Adv Technol CAS Key Lab Human Machine Intelligence Synergy Sy Shenzhen 518055 Peoples R China;

    Chinese Acad Sci Shenzhen Inst Adv Technol CAS Key Lab Human Machine Intelligence Synergy Sy Shenzhen 518055 Peoples R China;

    Panyu Cent Hosp Guangzhou 511400 Guangdong Peoples R China;

    Panyu Cent Hosp Guangzhou 511400 Guangdong Peoples R China;

    Chinese Acad Sci Shenzhen Inst Adv Technol CAS Key Lab Human Machine Intelligence Synergy Sy Shenzhen 518055 Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    muscle oxygenation; near-infrared spectroscopy; signal reconstruction; spatial discrimination;

    机译:肌肉氧合;近红外光谱;信号重建;空间歧视;