To improve the accuracy of your UV-A, UV-B and UV-E measurement results, Kipp & Zonen (The Netherlands) have developed the unique UVIATOR software package. Each Kipp & Zonen UVS radiometer is already supplied with extensive factory calibration data. This allows manual correction of the data to minimize errors. UVIATOR takes this a step further by carrying out the process automatically and providing graphical visualization of the results. Combining UVIATOR software with the spectral characteristics of the radiometer, corrects the mismatch between the actual sensor response and the ideal sensor response. This first step enables further corrections to be made to compensate for changing conditions of the UV spectrum. The correction methodology is based on an atmosphere transmission model and the use of the Ozone Monitoring Instrument (OMI) satellite data that can be retrieved from the internet. This satellite gives the total Ozone column density based on position (longitude and latitude) and time (GMT).
机译:为提高UV-A,UV-B和UV-E测量结果的准确性,Kipp&Zonen(荷兰)开发了独特的UVIATOR软件包。每台Kipp&Zonen UVS辐射计已经提供了广泛的工厂校准数据。这允许手动校正数据以最大程度地减少错误。 UVIATOR通过自动执行该过程并提供结果的图形可视化,使这一步骤更进一步。将UVIATOR软件与辐射计的光谱特性结合使用,可以纠正实际传感器响应与理想传感器响应之间的不匹配。该第一步使得能够进行进一步的校正以补偿UV光谱的变化条件。校正方法基于大气传输模型和臭氧监测仪(OMI)卫星数据的使用,这些数据可以从互联网上获取。该卫星根据位置(经度和纬度)和时间(GMT)得出臭氧总柱密度。