A total of 23 cross-flow heat exchangers having crimped spiral configurations is studied. The effect of tube diameter, fin spacing, transverse tube pitch, and tube arrangements are examined. For the inline arrangement, the pressure drop increases with the rise of tube diameter but the associated heat transfer coefficient decreases with it. The increase of fin height also gives rise to considerable increase of pressure drop and decrease of heat transfer coefficients for the inline arrangement. However, for the staggered arrangement, the effect of the fin height on the pressure drop is much smaller than that of the inline arrangement due to the major contribution to the total pressure drops from the blockage of the airflow from staggered arrangement. Effect of the fin spacing on the air side performance is strongly related to the transverse tube pitch for both inline and staggered arrangements. Correlations of the present crimped spiral fins in both staggered and inline arrangements are developed. The proposed correlations give fairly good predictive ability against the present test data.
机译:总共研究了23个具有卷曲螺旋结构的错流热交换器。检查管直径,散热片间距,横向管间距和管布置的影响。对于直列式布置,压降随管径的增加而增加,但相关的传热系数随之​​降低。翅片高度的增加还引起串联布置的压降的显着增加和传热系数的减小。然而,对于交错布置,由于对交错布置的气流的阻塞对总压降的主要贡献,翅片高度对压降的影响远小于串联布置的影响。对于直列式和交错式布置,翅片间距对空气侧性能的影响都与横向管间距密切相关。发展了目前的卷曲螺旋翅片在交错排列和直列排列中的相关性。所提出的相关性对当前的测试数据具有相当好的预测能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号