A comparison of mass transfer between a plate and submerged conventional and multichannel impinging jets

机译:平板与淹没式常规和多通道撞击射流之间的传质比较

获取原文
获取原文并翻译 | 示例
       

摘要

This study presents a work on the comparison of mass transfer distribution on a plate subjected to impingement by a conventional impinging jet (CIJ) and multichannel conventional impinging jet (MCIJ). The local mass transfer coefficients were measured by the electrochemical limiting diffusion current technique (ELDCT). The jet Reynolds number varied in the range of 10,950-50,800 and jet-to-plate distance 2d-10d, where d is the nozzle diameter. The local mass transfer values were recorded beginning from the impingement point to a radial distance of approximately 15d. The distribution of the local mass transfer coefficients (LMTC) was compared for both jet systems.
机译:这项研究提出了一项工作,比较了传统冲击射流(CIJ)和多通道常规冲击射流(MCIJ)承受冲击的板上的传质分布。通过电化学极限扩散电流技术(ELDCT)测量局部传质系数。雷诺射流数在10,950-50,800范围内变化,射流与印版的距离为2d-10d,其中d为喷嘴直径。从撞击点到大约15d的径向距离记录了局部传质值。比较了两种射流系统的局部传质系数(LMTC)的分布。