Rapid diagnostic tools for Helicobacter pylori are important in endoscopy. To assess the accuracy of a new 5-min rapid urease test (UFT300, ABS Cernusco, sul Naviglio, Italy) compared with the 1-h Pyloritek (Serim Laboratories, Elkhart, IN) and the 24-h CLO test (Kimberly-Clark Ballard Medical Products, Roswell, GA), consecutive dyspeptic patients referred to our unit for endoscopy were prospectively studied. All patients underwent a 13C-urea-breath test, histology and the UFT300 (ABS; Cernusco, sul Naviglio, Italy). Two additional rapid urease tests were performed. Patients were deemed infected when both 13C-UBT and histology were positive. Rapid urease tests were read at 1, 5, and 60 min, respectively. Of the 375 enrolled patients, 45.3% were infected with H. pylori. The sensitivity of the new 5-min rapid urease test 300 was 90.3, 94.5, and 96.2% at 1, 5, and 60 min, respectively (specificity 100%). The Pyloritek and the new 5-min rapid urease test were comparable, but the CLO test was not reliable at 5 and 60 min. In conclusion, the new 5-min rapid urease test is comparable to the Pyloritek test, but the CLO test is significantly less sensitive at early time points. Reading the test results at 1 min may increase false-negative results with decreasing sensitivity.
机译:幽门螺杆菌的快速诊断工具在内窥镜检查中很重要。为了评估新的5分钟快速尿素酶测试(UFT300,ABS Cernusco,意大利纳维利奥市)与1小时Pyloritek(Serim实验室,埃尔克哈特,印第安纳州)和24小时CLO测试(Kimberly-Clark)的准确性Ballard Medical Products,佐治亚州罗斯威尔市),对连续性消化不良的患者进行了前瞻性研究,这些消化不良患者被转介到我科进行内镜检查。所有患者均进行了 13 C-尿素呼气试验,组织学检查和UFT300(ABS; Cernusco,意大利纳维利奥市)。进行了另外两个快速尿素酶测试。当 13 C-UBT和组织学均为阳性时,患者被视为感染。快速尿素酶测试分别在1、5和60分钟读取。在375名患者中,有45.3%感染了幽门螺杆菌。新的5分钟快速尿素酶测试300在1分钟,5分钟和60分钟时的灵敏度分别为90.3%,94.5%和96.2%(特异性100%)。 Pyloritek和新的5分钟快速尿素酶测试具有可比性,但CLO测试在5分钟和60分钟时不可靠。总之,新的5分钟快速尿素酶测试与Pyloritek测试相当,但是CLO测试在早期时间点的灵敏度明显较低。在1分钟内读取测试结果可能会增加假阴性结果,同时降低灵敏度。

著录项

  • 来源
    《Internal and Emergency Medicine》 |2010年第1期|41-47|共7页
  • 作者单位

    Department of Internal Medicine and Gastroenterology, S. Orsola Hospital, University of Bologna, Via Massarenti 9, 40138 Bologna, Italy;

    Versilia Hospital, Lido di Camaiore, Italy;

    Gastroenterology Unit, University of Brescia, Brescia, Italy;

    Department of Internal Medicine and Gastroenterology, S. Orsola Hospital, University of Bologna, Via Massarenti 9, 40138 Bologna, Italy;

    Department of Internal Medicine and Gastroenterology, S. Orsola Hospital, University of Bologna, Via Massarenti 9, 40138 Bologna, Italy;

    Department of Internal Medicine and Gastroenterology, S. Orsola Hospital, University of Bologna, Via Massarenti 9, 40138 Bologna, Italy;

    Department of Internal Medicine and Gastroenterology, S. Orsola Hospital, University of Bologna, Via Massarenti 9, 40138 Bologna, Italy;

    Windeyer Institute of Medical Sciences, University College London, London, UK;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Helicobacter pylori; Diagnosis; Gastritis; Peptic ulcer;

    机译:幽门螺杆菌;诊断;胃炎;消化性溃疡;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号