This work analyzes the patch-clamp technique, which is the gold standard for ion channel measurements in electrophysiology, as well as the required instrumentation and main interferences that may affect the measurement accuracy. Different sources of degradation are evaluated, such as failure in headstage cooling and pipette/electrode impedance compensation systems, electromagnetic interference (EMI) coupling from environmental wireless signals, and noise coupling from power supplies and/or the peristaltic pump motor. Robotized patch-clamp measurement systems are also considered. Experimental evaluation of the possible effects on patch-clamp metrological performance and some countermeasures to mitigate them are discussed. Daily recordings are presented to show the effects of interferences on ion channel drug analysis.
机译:这项工作分析了膜片钳技术,这是电生理学中离子通道测量的金标准,以及可能影响测量精度的所需仪器和主要干扰。评估了不同的降解源,例如前端冷却系统和移液器/电极阻抗补偿系统的故障,来自环境无线信号的电磁干扰(EMI)耦合以及来自电源和/或蠕动泵电机的噪声耦合。还考虑了自动膜片钳测量系统。讨论了可能对膜片钳计量性能产生影响的实验评估,以及减轻其影响的一些对策。提供每日记录以显示干扰对离子通道药物分析的影响。