AC-DC difference from different type of AC-DC transfer standards placed under step humidity change conditions were measured at 200 V, 600 V, and 1 kV in the frequency range from 40 Hz to 100 kHz. The measured results have shown that the humidity affects the AC-DC difference of a high voltage AC-DC transfer standard significantly at high frequencies and that a first order differential equation can be used to model the behavior. The humidity coefficients of the model are found to be frequency dependent and the time constants are related to the change of the humidity. Furthermore, the humidity effect was also found to be device dependent due to the construction of the range resistor. It will imply consequences for the measuring procedures of further international comparisons in the field of AC-DC transfer.
机译:在200 V,600 V和1 kV的40 Hz至100 kHz频率范围内,测量了在阶跃湿度变化条件下与不同类型的AC-DC传输标准的AC-DC差异。测量结果表明,湿度在高频下会显着影响高压AC-DC传输标准的AC-DC差,并且可以使用一阶微分方程对行为进行建模。发现模型的湿度系数与频率有关,并且时间常数与湿度的变化有关。此外,由于范围电阻器的结构,还发现湿度效应与设备有关。这将对交流-直流转换领域的进一步国际比较的测量程序带来影响。