The current 3/spl times/10/sup -5/ relative combined uncertainty the isotope amount ratio measurements in natural Si must be improved in order to obtain a relative combined uncertainty on the molar mass smaller than 1/spl times/10/sup -7/. One of the problems is the isotopic effect, which accompanies adsorption/desorption processes of SiF/sub 4/ in the mass spectrometer inlet system. The value of M(Si) observed in 1994/95 was confirmed in this work to within 10/sup -7/M(Si), which means that the adsorption/desorption models developed are (quantitatively) correct to describe and predict isotopic effects due to memory at uncertainty levels of /spl les/1/spl times/10/sup -5/ R and /spl les/1/spl times/10/sup -7/ M(Si). It also shows that the previously measured isotope amount ratio values and derived molar masses have a lower uncertainty. The results obtained by using models compare well with those obtained after chemical cleaning of the mass spectrometer inlet system and reduce the relative combined uncertainty from 3/spl times/10/sup -7/ M(Si) to 1.3/spl times/10/sup -7/ M(Si). The new M(Si) for the "Avogadro Crystal" WASO 17.2 is 28.085 384 2 (35) g/spl middot/moi/sup -1/ as compared to 28.085 383 1 (89) g mol/sup -1/ previously obtained. The new value of the Avogadro constant is 6.022 136 7 (48)/spl times/10/sup 23/ mol/sup -1/ as compared to 6.022 136 5 (51)/spl times/10/sup 23/ mol/sup -1/ previously obtained.
机译:当前的3 / spl times / 10 / sup -5 /相对组合不确定度必须改善天然Si中同位素量比的测量,以便获得摩尔质量小于1 / spl times / 10 / sup-的相对组合不确定度- 7 /。问题之一是同位素效应,它伴随着质谱仪入口系统中SiF / sub 4 /的吸附/解吸过程。在这项工作中,在1994/95年观测到的M(Si)值被证实在10 / sup -7 / M(Si)之内,这意味着开发的吸附/解吸模型(定量)是正确的,可以描述和预测同位素效应由于记忆的不确定性水平为/ spl les / 1 / spl times / 10 / sup -5 / R和/ spl les / 1 / spl times / 10 / sup -7 / M(Si)。它还表明,先前测得的同位素量比值和导出的摩尔质量具有较低的不确定性。使用模型获得的结果与质谱仪进样口系统化学清洗后获得的结果相当,并将相对组合不确定度从3 / spl次/ 10 / sup -7 / M(Si)降低到1.3 / spl次/ 10 / sup -7 / M(Si)。 “ Avogadro晶体” WASO 17.2的新M(Si)为28.085 384 2(35)g / spl middot / moi / sup -1 /,而之前获得的28.085 383 1(89)g mol / sup -1 / 。 Avogadro常数的新值是6.022 136 7(48)/ spl次/ 10 / sup 23 / mol / sup -1 /,而6.022 136 5(51)/ spl次/ 10 / sup 23 / mol / sup -1 / -1 /先前获得的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号