A new method for calibrating ac voltage waveforms based on measuring the difference relative to a synchronously synthesized waveform supplied from a programmable Josephson array is presented. In order to test the accuracy of this approach, the differences between two Josephson waveforms have been measured at the $pm$1.2-V level for frequencies up to 5 kHz. The uncertainties achieved are at least a factor of ten lower than those from the direct sampling method. Below 400 Hz, this new method gives an uncertainty of $5 times 10^{-8} (k = 1)$, while at 1 kHz, the uncertainty is about $2 times 10^{-7} (k = 1)$.
机译:提出了一种新的校准交流电压波形的方法,该方法基于测量相对于可编程约瑟夫森阵列提供的同步合成波形的差异。为了测试此方法的准确性,已针对频率高达5 kHz的$ pm $ 1.2-V电平测量了两个约瑟夫森波形之间的差异。所获得的不确定度至少比直接采样法的不确定度低十倍。在400 Hz以下,这种新方法的不确定度为$ 5乘10 ^ {-8}(k = 1)$,而在1 kHz时,不确定度约为$ 2乘以10 ^ {-7}(k = 1)$。