Factory acceptances tests (FATs) of a new high-voltage (HV) rotating machine include comprehensive diagnostic tests of the finished stator winding insulation system. From these tests, the end user obtains the baseline data for the condition monitoring performed during the machine?s operating life. The design geometry of the stator windings and manufacturing processes used to produce them will affect the dielectric test results. There is a significant challenge in comparing the test results from different stators to obtain a statistically useful sample for an acceptance test database. This article compares the dielectric test results from the 14.4-kV windings of several new 1,800-r/min, 26.1-MW (35,000-hp) centrifugal compressor synchronous motor stators of identical design, built for two U.S. chemical plants. The results are compared with those from accompanying sacrificial coils. The stator diagnostic tests include the dissipation factor (DF) or tan delta, power factor tip up (PFTU) or delta tan delta, offline partial discharge (PD), corona inspection with an ultraviolet (UV) analyzer, and online PD. Sacrificial coils produced and processed alongside each stator receive the specified American Petroleum Institute (API) coil acceptance tests and corona inspection with a UV analyzer. The PD measurements on the sample coils were repeated at an elevated voltage, and the results were compared with the corona inspection observations. This article shares the comparative analysis of the stator and coil test results as an excellent example of the baseline FAT data.
机译:新型高压(HV)旋转电机的工厂验收测试(FAT)包括完成的定子绕组绝缘系统的综合诊断测试。从这些测试中,最终用户获得了在机器使用寿命期间进行状态监控的基准数据。定子绕组的设计几何形状以及用于生产定子绕组的制造工艺将影响介电测试结果。比较不同定子的测试结果,以获得用于验收测试数据库的统计上有用的样本,这是一个巨大的挑战。本文比较了为两个美国化工厂建造的,具有相同设计的几台新型1800r / min,26.1MW(35,000hp)离心压缩机同步电动机定子的14.4kV绕组的介电测试结果。将结果与随附的牺牲线圈的结果进行比较。定子诊断测试包括耗散因数(DF)或损耗角正切,功率因数增大(PFTU)或损耗角正切差,离线局部放电(PD),使用紫外线(UV)分析仪进行电晕检查以及在线PD。与每个定子一起生产和加工的牺牲线圈接受指定的美国石油协会(API)线圈验收测试,并使用紫外线分析仪进行电晕检查。在高电压下重复对样品线圈的PD测量,并将结果与​​电晕检查观察结果进行比较。本文分享了定子和线圈测试结果的对比分析,作为基准FAT数据的一个很好的例子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号