High-Voltage Power Supply for Ozone Generation Based on Piezoelectric Transformer

机译:基于压电变压器的臭氧发生器高压电源

获取原文
获取原文并翻译 | 示例
       

摘要

Even though, nowadays, piezoelectric transformers (PTs) are only available with low power rating, there exist several low-power applications of ozone generation in which the use of this novel technology could be advantageous. Hence, the aim of this paper is to evaluate the possibilities of using PTs in the implementation of high-voltage power supplies for ozone generation. First, the possible topologies that can be used to drive the PT are identified. Then, the half-bridge inverter operating under zero-voltage switching (ZVS) is investigated, and the effect of the silent discharge generator (SDG) on the converter operation is analyzed. A new control circuit that allows the ZVS operation is proposed. The control circuit operates in closed loop by measuring the phase between the PT's resonant current and the switching pattern and adjusting the switching frequency to the optimum value to assure ZVS. A laboratory prototype for a 6-W SDG was tested, and obtained experimental results are shown.
机译:即使如今,仅提供低额定功率的压电变压器(PT),但仍存在臭氧生成的几种低功率应用,其中使用这种新颖技术可能会有所优势。因此,本文的目的是评估在实现臭氧发生器的高压电源中使用PT的可能性。首先,确定可用于驱动PT的可能拓扑。然后,研究了在零电压开关(ZVS)下工作的半桥逆变器,并分析了无声放电发生器(SDG)对转换器工作的影响。提出了一种允许ZVS操作的新控制电路。控制电路通过测量PT的谐振电流和开关模式之间的相位并将开关频率调整到最佳值以确保ZVS,从而以闭环方式工作。测试了6-W SDG的实验室原型,并显示了获得的实验结果。