首页> 外文期刊>Industry Applications, IEEE Transactions on >A Comparative Study of Methods for Estimating Virtual Flux at the Point of Common Coupling in Grid-Connected Voltage Source Converters With LCL Filter
【24h】

A Comparative Study of Methods for Estimating Virtual Flux at the Point of Common Coupling in Grid-Connected Voltage Source Converters With LCL Filter

机译:具有LCL滤波器的并网电压源转换器中公共耦合点的虚拟通量估算方法的比较研究

获取原文
获取原文并翻译 | 示例
           

摘要

Grid synchronization based on virtual flux (VF) estimation allows for control of grid-connected power converter without depending on ac-voltage measurements. This is useful in voltage-sensor-less applications for reducing cost and complexity of the control hardware, and can be utilized in case of limited reliability or availability of voltage measurements at the intended point of synchronization to the grid. However, for voltage source converters (VSC) with LCL filters, the influence of the capacitor current must be taken into account to ensure accurate VF estimation at the point of common coupling (PCC) with the grid. This paper presents a comparative evaluation of three VF-based methods for grid synchronization of VSCs with LCL filters, with three different ways of obtaining the capacitor current. The VF estimation in the first method is based only on the measured converter currents. The second method includes capacitor voltage measurements used for estimating the capacitor currents, while the capacitor currents are measured in the third approach. Comparative results from time-domain simulations are presented, demonstrating good performance of the estimation and accurate control of the active and reactive power at the PCC with all three methods, as long as sufficiently accurate filter parameters and current measurements are available. However, the approach based on capacitor current measurements is sensitive to noise due to the high ripple current compared with the fundamental frequency current in the capacitors. The operation of a converter with VF-based grid synchronization including estimation of the capacitor current is demonstrated by experimental results, verifying the voltage sensor-less operation with LCL filter.
机译:基于虚拟磁通(VF)估计的电网同步可控制并网功率转换器,而无需依赖于交流电压测量。这在无电压传感器的应用中很有用,可以降低控制硬件的成本和复杂性,并且可以在与电网同步的预期点上电压测量的可靠性或可用性有限的情况下使用。但是,对于带有LCL滤波器的电压源转换器(VSC),必须考虑电容器电流的影响,以确保在与电网的公共耦合(PCC)点处进行准确的VF估算。本文通过三种不同的获取电容器电流的方法,对三种基于VF的具有LCL滤波器的VSC的电网同步方法进行了比较评估。第一种方法中的VF估计仅基于测得的转换器电流。第二种方法包括用于估计电容器电流的电容器电压测量,而在第三种方法中测量电容器电流。给出了时域仿真的比较结果,证明了在所有三种方法下,只要有足够精确的滤波器参数和电流测量值,PCC的估计性能和对有功功率和无功功率的精确控制都具有良好的性能。然而,与电容器中的基频电流相比,基于电容器电流测量的方法由于高纹波电流而对噪声敏感。实验结果证明了具有基于VF的电网同步的转换器的运行,其中包括估算电容器电流,并通过LCL滤波器验证了无电压传感器的运行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号