首页> 外文期刊>Industry Applications, IEEE Transactions on >Reconfiguration of T-Type Inverter for Direct Torque Controlled Induction Motor Drives Under Open-Switch Faults
【24h】

Reconfiguration of T-Type Inverter for Direct Torque Controlled Induction Motor Drives Under Open-Switch Faults

机译:开路故障下用于直接转矩控制感应电动机驱动器的T型逆变器的重新配置

获取原文
获取原文并翻译 | 示例
       

摘要

This paper identifies possible topological reconfigurability of a T-type inverter for direct torque controlled (DTC) induction motor drives when an open-switch fault occurs. In open-switch fault, inverter current path is different than normal path. This causes undesirable inverter switching states. Since DTC is based on a voltage vector selection criterion, open-switch fault causes ambiguous torque control. Analysis of DTC drive under two different inverter open-switch fault conditions viz. half-bridge and neutral-point switch fault are presented. The operation of the inverter in DTC mode against faults is achieved by simple topological reconfiguration.
机译:本文确定了发生开路开关故障时,用于直接转矩控制(DTC)感应电动机驱动器的T型逆变器的拓扑可重构性。在开路故障中,逆变器电流路径与正常路径不同。这导致不期望的逆变器开关状态。由于DTC基于电压矢量选择标准,因此断路故障会导致转矩控制不明确。在两种不同的逆变器断开开关故障条件下的故障诊断代码驱动器分析。介绍了半桥和中性点开关故障。通过简单的拓扑重新配置,逆变器可以在DTC模式下针对故障运行。