This article deals with the determination of the rotor time-constant of an induction machine by performing a flux-decay test in generic load conditions. The flux-decay transient occurs when the supply stator voltage is turned off suddenly. In this way, from the decay envelope of stator back-electromotive forces and, in the case of the wound rotor machine, from that of the rotor currents, the rotor time-constant can be extrapolated with a high level of accuracy. In this article, an in-depth analysis of this methodology is reported, whose validation has been carried out on both the squirrel cage and wound rotor motors. The estimated value of rotor time-constant can be used for the machine torque regulation, using the well-known control schemes presented in the literature and whose performance in the low-speed operation is affected by the detuning of this parameter. Since the inverter-fed motors nowadays characterize most of the share in the market of adjustable speed drives, experimental results concerning the flux decay test performed under the pulsewidth modulation supply are also presented.
机译:本文通过在通用负载条件下执行磁通衰减测试来涉及诱导机的转子时间常数。当供应定子电压突然关闭供电定子电压时,会发生磁通衰减瞬态。以这种方式,从定子背部电动势的衰减包络,并且在缠绕转子机的情况下,从转子电流的情况下,转子时间常数可以以高精度推断。在本文中,报告了对该方法的深入分析,其验证已经在鼠笼和伤口转子电动机上进行。转子时间常数的估计值可用于机器扭矩调节,使用文献中呈现的众所周知的控制方案,并且在低速操作中的性能受到该参数的影响影响。由于现在逆变器供给电机表征了可调速度驱动器市场中的大部分份额,因此还提出了关于在脉冲宽度调制供应下进行的磁通衰减试验的实验结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号