The performance of Voltage Source Inverter (VSI) is affected by power semiconductor nonlinearities, dead time, and control delay. The compensation of these nonlinear effects is necessary to meet requirements in terms of current quality and high efficiency, especially for grid-connected power conversion systems. In this paper, the effects of nonlinearities are widely analyzed and a new compensation technique for a steady-state current-controlled VSI is proposed. It is based on a step-by-step voltage compensation on the basis of the current error evaluated within each control interval. As a result, a complete compensation is achieved within a whole period of the fundamental. To cope with the zero-current clamping effect, the proposed compensation technique is implemented in a recursive way. For slow-dynamic applications, such as photovoltaic systems, this method allows achieving high performance with very low computational requirements.
机译:电压源逆变器(VSI)的性能受功率半导体非线性,死区时间和控制延迟的影响。为了满足电流质量和高效率方面的要求,必须对这些非线性效应进行补偿,特别是对于并网电源转换系统。在本文中,广泛地分析了非线性的影响,并提出了一种用于稳态电流控制VSI的新补偿技术。它基于在每个控制间隔内评估的电流误差的逐步电压补偿。结果,在基本面的整个周期内实现了完全补偿。为了应对零电流钳位效应,提出的补偿技术以递归的方式实现。对于诸如光伏系统之类的低动态应用,该方法可以以非常低的计算需求实现高性能。