In this paper, a novel field-weakening scheme for the induction machine is presented. The proposed algorithm, based on the voltage control strategy, ensures the maximum torque operation over the entire field-weakening region without using the machine parameters. Also, by introducing the direct field-oriented (DFO) control, which is insensitive to the variation of machine parameters in the field-weakening region, the drive system can obtain robustness to parameter variations. Moreover, the speed sensorless control can be achieved in the very-high-speed range, where the utilization of the speed sensor is limited. Experimental results for the laboratory induction motor drive system confirm the validity of the proposed control algorithm.
机译:本文提出了一种新颖的感应电机磁场弱化方案。所提出的算法基于电压控制策略,可在不使用电机参数的情况下确保在整个弱磁区域内实现最大转矩操作。此外,通过引入对磁场弱化区域中的机器参数的变化不敏感的直接面向磁场的(DFO)控制,驱动系统可以获得对参数变化的鲁棒性。此外,可以在速度传感器的使用受到限制的非常高的速度范围内实现无速度传感器的控制。实验室感应电动机驱动系统的实验结果证实了所提出的控制算法的有效性。