The modifying effect of the building envelope on population exposure to PM_(2.5) from outdoor sources

机译:建筑围护结构对室外暴露于PM_(2.5)的人群的影响

获取原文
获取原文并翻译 | 示例
       

摘要

A number of studies have estimated population exposure to PM_(2.5) by examining modeled or measured outdoor PM_(2.5) levels. However, few have taken into account the mediating effects of building characteristics on the ingress of PM_(2.5) from outdoor sources and its impact on population exposure in the indoor domestic environment. This study describes how building simulation can be used to determine the indoor concentration of outdoor-sourced pollution for different housing typologies and how the results can be mapped using building stock models and Geographical Information Systems software to demonstrate the modifying effect of dwellings on occupant exposure to PM_(2.5) across London. Building archetypes broadly representative of those in the Greater London Authority were simulated for pollution infiltration using EnergyPlus. In addition, the influence of occupant behavior on indoor levels of PM_(2.5) from outdoor sources was examined using a temperature-dependent window-opening scenario. Results demonstrate a range of I/O ratios of PM_(2.5), with detached and semi-detached dwellings most vulnerable to high levels of infiltration. When the results are mapped, central London shows lower I/O ratios of PM_(2.5) compared with outer London, an apparent inversion of exposure most likely caused by the prevalence of flats rather than detached or semi-detached properties.
机译:许多研究通过检查建模或测量的室外PM_(2.5)水平来估算人口暴露于PM_(2.5)的程度。但是,很少有人考虑到建筑特性对室外来源PM_(2.5)的侵入的中介作用及其对室内室内环境中人口暴露的影响。这项研究描述了如何使用建筑物模拟来确定不同住房类型的室外污染源的室内浓度,以及如何使用建筑物模型和地理信息系统软件来绘制结果图,以说明住房对乘员暴露于环境的影响。整个伦敦的PM_(2.5)。使用EnergyPlus模拟了大伦敦地区代表的建筑原型的污染渗透情况。此外,使用与温度有关的开窗情景,研究了乘员行为对室外来源室内PM_(2.5)水平的影响。结果表明,PM_(2.5)的I / O比率范围较大,其中独立式和半独立式住宅最容易受到高渗透率的影响。映射结果时,伦敦市中心的PM_(2.5)的I / O比伦敦外围地区的I / O比率低,这很可能是由于公寓的普及而不是独立式或半独立式房屋引起的,显然是暴露的反转。

著录项

  • 来源
    《Indoor Air》 |2014年第6期|639-651|共13页
  • 作者单位

    Bartlett School of Graduate Studies, UCL Central House 14 Upper Woburn Place, London WC1H ONN, UK;

    Bartlett School of Graduate Studies, UCL, London, UK;

    Bartlett School of Graduate Studies, UCL, London, UK;

    UCL Energy Institute, The Bartlett, UCL, London, UK;

    Bartlett School of Graduate Studies, UCL, London, UK;

    UCL Energy Institute, The Bartlett, UCL, London, UK;

    Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Oxfordshire, UK;

    Bartlett School of Graduate Studies, UCL, London, UK;

    Department of Architecture and Built Environment, University of Nottingham, Nottingham, UK;

    UCL Energy Institute, The Bartlett, UCL, London, UK;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    PM_(2.5); Indoor air quality; Building stock model; EnergyPlus; Geographical information systems;

    机译:PM_(2.5);室内空气质量建筑库存模型;EnergyPlus;地理信息系统;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号