首页> 外文期刊>Indoor Air >Impact of culture media and sampling methods on Staphylococcus aureus aerosols
【24h】

Impact of culture media and sampling methods on Staphylococcus aureus aerosols

机译:培养介质与取样方法对金黄色葡萄球菌气溶胶的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Staphylococcus aureus has been detected indoors and is associated with human infection. Reliable quantification of S.aureus using a sampling technique followed by culture assay helps in assessing the risks of human exposure. The efficiency of five culture media and eight sampling methods in recovering S.aureus aerosols were evaluated. Methods to extract cells from filters were also studied. Tryptic soy agar (TSA) presented greater bacterial recovery than mannitol salt agar (MSA), CHROMagar staph aureus, Chapman stone medium, and Baird–Park agarose (P<0.05). Moreover, 93±2%–95±2% and 42±1%–49±2% of S.aureus were, respectively, recovered by a 15-min heating of gelatin filters and 2-min vortex of polycarbonate (PC) filters. Evaluation of two filtration (IOM with gelatin filter and cassette with PC filter), two impaction (Andersen 1-STG loaded with TSA and MSA) and four impingement methods [AGI-30 and BioSampler filled with Tween mixture (TM) and phosphate-buffered saline (PBS)] revealed the BioSampler/TM performed best over 30 and 60min of sampling (P<0.05), while low recovery efficiencies were associated with the IOM/gelatin, cassette/PC, and AGI-30/PBS combinations (P<0.05). In addition to BioSampler/TM, collecting S. aureus onto TSA from the Andersen 1-STG is also recommended, as it is the second best method at the 60-min sampling (P<0.05).
机译:金黄色葡萄球菌在室内发现并与人类感染有关。使用采样技术可靠地定量S.aureus,然后进行培养方法,有助于评估人体暴露的风险。评估了五种培养介质和八种采样方法的效率评价。评估了S.aureus气溶胶。还研究了从过滤器中提取细胞的方法。胰蛋白酶大豆琼脂(TSA)呈现出比甘露醇盐琼脂(MSA),Chromagar Staph Aureus,Chapman Stone Medium和Baird-Park琼脂糖(P <0.05)的细菌恢复更大的细菌恢复。此外,分别93±2%-95±2%和42±1%-49±2%均由明胶过滤器的15分钟加热和2分钟的聚碳酸酯(PC)过滤器来回收。评价两种过滤(IOM,带有PC过滤器的明胶过滤器和盒),两个撞击(Andersen 1-STG加载TSA和MSA)和四种冲击方法[AGI-30和BioSampler填充有补间混合物(TM)和磷酸盐缓冲盐水(PBS)]显示BioSampler / TM最佳的采样超过30和60分钟(P <0.05),而低收回效率与IOM / Gelatin,Cassette / PC和AGI-30 / PBS组合有关(P < 0.05)。除了BioSampler / TM之外,还建议使用Andersen 1-STG的Crought S.金黄色葡萄球菌,因为它是60分钟采样的第二种最佳方法(P <0.05)。

著录项

  • 来源
    《Indoor Air》 |2015年第5期|1-11|共11页
  • 作者

    C.-W. Chang; L.-J. Wang;

  • 作者单位

    Institute of Environmental Health College of Public Health National Taiwan University Taipei Taiwan 2. Center for Research on Environmental and Occupational Health National Taiwan University Taipei Taiwan 3. Research Center for Genes Environmental and Human Health National Taiwan University Taipei Taiwan;

    4. Institute of Occupational Medicine and Industrial Hygiene College of Public Health National Taiwan University Taipei Taiwan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Staphylococcus aureus; Culture media; Cassette; IOM; BioSampler; Andersen;