首页> 外文期刊>The Indian concrete journal >Pounding between adjacent buildings: Comparison of codal provisions
【24h】

Pounding between adjacent buildings: Comparison of codal provisions

机译:相邻建筑物之间的重击:比较规定

获取原文
获取原文并翻译 | 示例
       

摘要

It is not uncommon to find buildings in seismically active regions built adjacent to each other without following the prescribed codal separation distance. If the separation distance is insufficient, in the event of an earthquake, pounding may cause severe architectural and structural damage, and may even lead to the collapse of the structure. Seismic design codes suggest minimum separation distance between two adjacent structures; however, the spacing has to be enough to withstand earthquake excitations. To understand the effect of codal provisions on pounding, two buildings were idealised as linear single degree of freedom oscillators. The separation distance between them was provided following the codal provisions of select countries. By subjecting the buildings to five different ground motions the first impact force due to collision was calculated and the results were analysed to compare the codal provisions.
机译:在不遵循规定的分隔间距的情况下,在彼此相邻的地震活动区域中找到建筑物的情况并不少见。如果分隔距离不足,则在发生地震时,撞击可能会导致严重的建筑和结构损坏,甚至可能导致结构倒塌。抗震设计规范建议两个相邻结构之间的最小分隔距离。但是,该间距必须足以承受地震的激发。为了了解科达规定对撞击的影响,将两座建筑物理想化为线性单自由度振荡器。它们之间的间隔距离是根据某些国家的规定制定的。通过对建筑物进行五种不同的地面运动,计算了由于碰撞而产生的第一冲击力,并对结果进行了分析,以比较这些规定。