首页> 外文期刊>電子情報通信学会技術研究報告 >渦電流を用いた吊線の腐食劣化診断技術
【24h】

渦電流を用いた吊線の腐食劣化診断技術

机译:利用涡流的悬吊线腐蚀劣化诊断技术

获取原文
获取原文并翻译 | 示例

摘要

Several level of corrosion was added to the messenger wire of twisted zinc-coated steel for the opt-fiber communication, the residual thickness of zinc and section area of steel were measured by using trial manufactured Eddy current testing (ECT) meter, and developed the corroded wire diagnosis method by non-destructive method. Influence of the actual corrosion behavior to ECT signal become clear. Also, the estimation both of the residual thickness of zinc and section area of steel seems to be possible by using the evaluation of X-signal (V) and phase (degree). By obtain the corrosion rate of wire the life-time estimation seems to be possible. The other applicable method by ECT was also introduced.%光ファイバ通信ケーブル用吊線として用いられている亜鉛被覆鋼撚り線の定尺試験片に種々のレベルの腐食を付与し,試作した渦電流測定計器を用いて非接触で亜鉛の残存平均膜厚と鋼の残存平均断面積を測定し,架線の腐食劣化を非破壊で診断する方法について検討した.その結果,実際の腐食挙動が渦電流特性に及ぼす影響を明らかにした.また,渦電流のX信号(Ⅴ)と位相(度)を用いて評価することにより,亜鉛の残存膜厚と鋼の残存断面積を精度良く推定できる.また,吊線の腐食速度を別途把握することにより,余寿命評価が可能となる見通しを得た.渦電流を用いた他の応用例として,接触型渦電流法による局所亜鉛膜厚の測定技術や,非接触型渦電流法による内部損傷の検知方法についても紹介する.
机译:为了使光纤通讯,在绞合的镀锌钢的钢缆中增加了几种腐蚀程度,使用试制的涡流测试仪(ECT)测量了锌的残留厚度和钢的截面积,并开发了通过非破坏性方法对腐蚀金属丝进行诊断的方法。实际腐蚀行为对ECT信号的影响变得清晰。此外,通过使用X信号的评估,似乎可以估计锌的残余厚度和钢的截面积(V)和相(度)通过获得导线的腐蚀速率,似乎可以进行寿命估算。还介绍了ECT的另一种适用方法。%锌涂层用作光纤通信电缆的悬挂线架空线的腐蚀是通过对标准长度的多股钢丝试件施加不同程度的腐蚀并使用原型涡流测量仪测量锌的残留平均膜厚和不接触钢的平均横截面积来测量的。我们检查了恶化的非破坏性诊断方法。结果,澄清了实际腐蚀行为对涡流特性的影响。另外,通过使用涡流的X信号(V​​)和相位(度)进行评估,可以准确估算锌的残留膜厚和钢的残留横截面积。另外,我们获得了可以通过单独理解悬索的腐蚀速率来评估剩余寿命的前景。与其他使用涡流的应用一样,我们还将介绍一种通过接触涡流方法测量局部锌膜厚度的技术,以及一种通过非接触涡流方法检测内部损伤的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号