Currently, small implantable medical devices are driven by batteries. However, the implanted device cannot be used to perform additional functions because of the battery energy limitations. To overcome this problem, we propose an energy transmission system that passes a high-frequency current though the human tissue between transmitting electrodes, which are placed on the body surface, and receiving electrodes, which are installed on the implanted device. By using an electromagnetic field simulator (SEMCAD X), we determine the maximum power supply at which the human body model developed at NICT can be reproduced. A maximum receiving power of 4.73 mW is obtained at a frequency of 10 MHz.%現在,体内埋込式小型医療機器の電源には電池が用いられているが,多機能化を行う場合には電力が不足してしまうため,非接触でのエネルギー伝送が必要となる.本稿では,体表面と体内埋込式小型医療機器にそれぞれ2枚1組の送受電電極を配置し,高周波電流を流すことでエネルギー伝送する方法について検討する.電磁界解析(SEMCAD X)により,NICTの数値人体モデルを参考に人体の形状のみを正確に再現したモデルを利用した場合での最大受電電力について検討した.その結果,10MHzで最大4.73mWの電力を確保していることを確認した.
机译:目前,小型植入式医疗设备由电池驱动,但是由于电池能量的限制,该植入式设备无法用于执行其他功能。为克服此问题,我们提出了一种能量传输系统,该系统可以通过电池传输高频电流通过放置在人体表面上的发射电极与安装在植入设备上的接收电极之间的人体组织,通过使用电磁场模拟器(SEMCAD X),我们确定了开发人体模型时的最大电源在NICT时代可以再现,在10 MHz的频率下可获得4.73 mW的最大接收功率。%目前,电池被用作植入式小型医疗设备的电源。由于电力短缺,因此需要非接触式能量传输。在本文中,我们讨论了一种通过在体表和小型可植入医疗设备上分别布置两对功率发送和接收电极并通过高频电流来传递能量的方法。通过电磁场分析(SEMCAD X),我们参考了NICT的人体数字模型,检查了仅使用精确再现人体形状的模型时的最大接收功率。结果,证实了在10MHz下确保了4.73mW的最大功率。