首页> 外文期刊>電気学会論文誌. A >The Influence of a Solid/Liquid Interface on electric Conduction Characteristics under Non-uniform Field in Transformer Oil
【24h】

The Influence of a Solid/Liquid Interface on electric Conduction Characteristics under Non-uniform Field in Transformer Oil

机译:变压器油中非均匀场下固液界面对导电特性的影响

获取原文
获取原文并翻译 | 示例
           

摘要

It is shown in this paper that the electric conduction in transformer oil is significantly affected by the presence of a solid/liquid interface. Using a blade-plane electrode geometry, we investigated the influence of an insulator inserted along the plane of symmetry of an electrode gap on conduction currents in transformer oil. Though the stationary relationship between current I and voltage V always showed the linear plots of V vs. I~1/3, conduction currents were prominently decreased by the presence of the insulator.
机译:本文表明,固/液界面的存在显着影响变压器油中的导电性。使用叶片平面电极的几何形状,我们研究了沿电极间隙的对称平面插入的绝缘子对变压器油中传导电流的影响。尽管电流I和电压V之间的固定关系总是显示V与I〜1/3的线性关系,但是由于绝缘子的存在,传导电流显着降低。