Phase Current Unbalance Estimation in Multiphase Buck Converters

机译:多相降压转换器中的相电流不平衡估计

获取原文
获取原文并翻译 | 示例
       

摘要

A method for estimating the phase current unbalance in a multiphase buck converter is presented. The method uses the information contained in the voltage drop at the input capacitor''s effective series resistance (ESR) to estimate the average current in each phase. Although the absolute estimation of the currents depends on the value of the ESR and is therefore not absolutely accurate, the relative estimates of the currents with respect to one other are shown to be very accurate. The method can be implemented with a low-rate down-sampling A/D converter and is not computationally intensive. Experimental results are presented, showing good agreement between the estimates and the measured values.
机译:提出了一种估算多相降压转换器中相电流不平衡的方法。该方法使用输入电容器的有效串联电阻(ESR)的压降中包含的信息来估算每相的平均电流。尽管电流的绝对估计值取决于ESR的值,因此不是绝对准确的,但电流相对于彼此的相对估计值显示非常准确。该方法可以用低速率下采样A / D转换器来实现,并且计算量不大。实验结果表明,估计值和测量值之间具有很好的一致性。