In this paper, a new technique for stator winding interturn fault detection in current-controlled permanent magnet synchronous machines is proposed. The method is based on online extraction of the second harmonic component of the voltage reference vector in the dq frame. It will be shown that the amplitude of this harmonic depends on the interturn fault severity and the fault detection is realized by comparing the magnitude of the control voltage second harmonic, derived using a proper time-domain transformation, to a predefined threshold. This is a low-cost method in CPU burden time. The experimental results show the validity of the proposed method.
机译:提出了一种电流控制永磁同步电机定子绕组匝间故障检测的新技术。该方法基于在线提取dq帧中电压参考矢量的二次谐波分量。将表明,该谐波的幅度取决于匝间故障的严重程度,并且通过将使用适当的时域变换得出的控制电压二次谐波的幅度与预定阈值进行比较,可以实现故障检测。这是CPU负担时间的一种低成本方法。实验结果证明了该方法的有效性。