Comparison of a Buck Converter and a Series Capacitor Buck Converter for High-Frequency, High-Conversion-Ratio Voltage Regulators

机译:用于高频,高转换比稳压器的Buck转换器和串联电容器Buck转换器的比较

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents an analytical and experimental comparison of a two-phase buck converter and a two-phase, series capacitor buck converter. The limitations of a conventional buck converter in high-current (10 A or more), and high-frequency (HF, 3-30 MHz) point-of-load voltage regulators with large voltage conversion ratios (10-to-1) are highlighted. The series capacitor buck converter exhibits desirable characteristics at HF, including lower switching loss, less inductor current ripple, automatic phase current balancing, duty ratio extension, and soft charging of the energy transfer capacitor. Analysis of the topologies indicates that switching loss and inductor core loss can dominate at HF. Results from side-by-side 12 V input, 1.2 V output hardware prototypes demonstrate that the series capacitor buck converter has up to 12 percentage points higher efficiency at 3 MHz and reduces power loss by up to 33% at full load (10 A). Some guidelines for inductor selection are provided, and a switch stress comparison reveals that the maximum converter switch stress is reduced by 30%.
机译:本文介绍了两相降压转换器和两相串联电容器降压转换器的分析和实验比较。传统降压转换器在大电流(10 A或更高)和具有大电压转换比(10:1)的高频(HF,3-30 MHz)负载点稳压器中的局限性是突出显示。串联电容器降压转换器在HF处表现出理想的特性,包括更低的开关损耗,更少的电感器电流纹波,自动相电流平衡,占空比扩展以及能量转移电容器的软充电。拓扑分析表明,开关损耗和电感器铁芯损耗在HF时可能占主导地位。并排的12 V输入,1.2 V输出硬件原型的结果表明,串联电容器降压转换器在3 MHz时的效率提高了12个百分点,并且在满载(10 A)时功耗降低了33%。 。提供了一些电感选择指南,并且比较了开关应力,发现转换器的最大开关应力降低了30%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号