The mathematical modeling of open-switch faults in two-level machine-side converters and the fault-tolerant current control of isotropic permanent-magnet synchronous generators are discussed in this paper. The proposed converter model is generic for any open-switch fault and independent of the operation mode of the electrical machine. The proposed fault-tolerant current control system gives improved control performance and reduced torque ripple under open-switch faults by modifying the antiwindup strategy, adapting the space-vector modulation scheme, and by injecting additional reference currents. The theoretical derivations of model and control are validated by comparative simulation and measurement results.
机译:本文讨论了两级电机侧变流器开路故障的数学模型以及各向同性永磁同步发电机的容错电流控制。所提出的转换器模型对于任何断路故障都是通用的,并且与电机的运行模式无关。拟议的容错电流控制系统通过修改反饱和策略,改编空间矢量调制方案并注入额外的参考电流,可以改善开路故障下的控制性能,并减小转矩脉动。通过比较仿真和测量结果验证了模型和控制的理论推导。