Two types of pure-silica-core fibers (one low-OH, Al-jacketed, one medium-OH, polyimide jacketed) suitable for use as sensing fibers for Raman-scattering-based temperature measurements in nuclear environments have been subjected to gamma and fission reactor irradiation tests. Spectral attenuation measurements were performed between 500 and 1500 nm with samples kept at room temperature, 80 and 300/spl deg/C. The Al-jacketed fiber was developed for use under ionizing radiation and showed lower loss compared with the polyimide-jacketed fiber at room temperature under gamma irradiation. Both fiber types showed similar spectra at room temperature with the main part of the loss originating from a band tail extending from the ultraviolet. Thermal bleaching of the radiation-induced defects was found to be effective in both fiber types. At 80/spl deg/C the loss in both fibers was compounded of a band at 625 nm together with the band tail from the ultraviolet, which now had a strength several times lower compared with room-temperature irradiations. At 300/spl deg/C, both fibers exhibited similar low-loss spectra, except for the band at 625 nm which reached levels of approximately /spl sim/2000 dB/km at an accumulated dose of 2.8/spl times/10/sup 4/ Gy(SiO/sub 2/). In light of the experimental spectral findings, selection of suitable Raman-distributed temperature sensors for nuclear plants can be made.
机译:适用于核环境中基于拉曼散射的温度测量的传感光纤的两种类型的纯硅纤芯光纤(一种低OH,有铝夹套,一种中等OH,有聚酰亚胺夹套)已经过γ和裂变反应堆辐照试验。光谱衰减测量是在500至1500 nm之间进行的,样品保持在室温下80至300 / spl deg / C。装有铝套的纤维被开发用于电离辐射,与在室温下γ射线辐照的带有聚酰亚胺套的纤维相比,损耗更低。两种纤维在室温下均显示出相似的光谱,损耗的主要部分来自紫外延伸的带尾。辐射引起的缺陷的热漂白被发现在两种纤维类型中都是有效的。在80 / spl deg / C时,两条光纤的损耗都由625 nm的一条带和来自紫外线的条带尾部加在一起,与紫外辐射相比,其强度现在降低了几倍。在300 / spl deg / C时,两条光纤均表现出相似的低损耗光谱,但在625 nm处的波段在2.8 / spl次/ sups累积剂量下达到大约/ spl sim / 2000 dB / km的水平。 4 / Gy(SiO / sub 2 /)。根据实验光谱发现,可以为核电站选择合适的拉曼分布温度传感器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号