首页> 外文期刊>IEEE Transactions on Nuclear Science >Comparison of Hotelling observer models and human observers in defect detection from myocardial SPECT imaging
【24h】

Comparison of Hotelling observer models and human observers in defect detection from myocardial SPECT imaging

机译:Hotelling观察者模型与人类观察者在心肌SPECT成像缺陷检测中的比较

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of this study was to compare defect detection performance using a channelized Hotelling observer with radially symmetric channel (RSC) and oriented channels (OC) to that found in a previously reported human observer ROC study (see K.J. LaCroix and B.M.W. Tsui, "An evaluation ofthe effect of nonuniform attenuation compensation on defect detection for Tc-99m myocardial SPECT images," J. Nucl. Med., vol. 38, p. 19P, 1997). The observer's task involved the detection of left-ventricular myocardial perfusion defects for Tc-99m sestamibi myocardial perfusion SPECT images. The images were reconstructed using the filtered-backprojection (FBP) algorithm without attenuation compensation or the maximum-likelihood expectation-maximization (ML-EM) algorithm with non-uniform attenuation compensation (AC). This was performed for cases with and without significant attenuation artifacts. The areas under the ROC curves for the Hotelling observers were calculated and compared to those for the human observers. The ML-EM reconstructed images (with AC) had high defect detectability across all anatomy types, while with FBP, a lower detectability was found for cases where the reconstructed images contained attenuation artifacts in the myocardium. Similar trends between the channelized Hotelling observer and those from the human observer study were found with both radially symmetric channel (RSC) and oriented-channel (OC) models. Further investigation of the channel models is needed to determine the number and alignment of orientations and the number and cutoff of frequency bands to improve agreement between human and Hotelling observer results.
机译:这项研究的目的是将带有径向对称通道(RSC)和定向通道(OC)的带通道Hotelling观测器的缺陷检测性能与先前报道的人类ROC研究中发现的性能进行比较(参见KJ LaCroix和BMW Tsui,“评估非均匀衰减补偿对Tc-99m心肌SPECT图像缺陷检测的效果,” J。Nucl。Med。,第38卷,第19P页,1997年。观察者的任务涉及检测Tc-99m西他米比心肌灌注SPECT图像的左心室心肌灌注缺陷。使用没有衰减补偿的滤波反投影(FBP)算法或具有非均匀衰减补偿(AC)的最大似然期望最大化(ML-EM)算法重建图像。这是针对具有和没有明显衰减伪影的情况执行的。计算出Hotelling观察者的ROC曲线下的面积,并将其与人类观察者的面积进行比较。 ML-EM重建图像(使用AC)在所有解剖结构类型中均具有较高的缺陷可检测性,而使用FBP,对于重建图像包含心肌中的衰减伪影的情况,发现的可检测性较低。在径向对称通道(RSC)和定向通道(OC)模型中,通道化的Hotelling观察者与人类观察者研究的相似趋势也被发现。需要进一步研究信道模型以确定方向的数量和对齐方式,以及频带的数量和截止频率,以改善人类和Hotelling观察者结果之间的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号