首页> 外文期刊>IEEE Transactions on Microwave Theory and Techniques >Precision Measurement Method for Cryogenic Amplifier Noise Temperatures Below 5 K
【24h】

Precision Measurement Method for Cryogenic Amplifier Noise Temperatures Below 5 K

机译:5 K以下低温放大器噪声温度的精密测量方法

获取原文
获取原文并翻译 | 示例

摘要

We report precision measurements of the effective input noise temperature of a cryogenic (liquid-helium temperature) monolithic-microwave integrated-circuit amplifier at the amplifier reference planes within the cryostat. A method is given for characterizing and removing the effect of the transmission lines between the amplifier reference planes and the input and output connectors of the cryostat. In conjunction with careful noise measurements, this method enables us to measure amplifier noise temperatures below 5 K with an uncertainty of 0.3 K. The particular amplifier that was measured exhibits a noise temperature below 5.5 K from 1 to 11 GHz, attaining a minimum value of 2.3 K+-0.3 K at 7 GHz. This corresponds to a noise figure of 0.034 dB+-0.004 dB. The measured amplifier gain is between 33.4 dB+-0.3 dB and 35.8 dB+-0.3 dB over the 1-12-GHz range.
机译:我们报告了低温恒温器内放大器基准面上的低温(液氦温度)单片微波集成电路放大器的有效输入噪声温度的精确测量。给出了一种方法,用于表征和消除放大器参考平面与低温恒温器的输入和输出连接器之间的传输线的影响。结合仔细的噪声测量,该方法使我们能够以低于0.3 K的不确定度来测量5 K以下的放大器噪声温度。所测量的特定放大器在1至11 GHz范围内的噪声温度低于5.5 K,达到了最小值在7 GHz下为2.3 K + -0.3K。这对应于0.034 dB + -0.004 dB的噪声系数。在1-12 GHz范围内,测得的放大器增益在33.4 dB + -0.3 dB和35.8 dB + -0.3 dB之间。