In this paper, dielectric constants of lossy organic liquids are measured using oscillation frequency shifts of a negative-resistance voltage-controlled oscillator (VCO). The design and working principle of the oscillator and the effect of material loss are presented in detail. The proposed method provides relatively large frequency shifts of 10-110 MHz for lossy test sample volumes of 50-200 μL whose dielectric constants are between 2-13 at 4.5 GHz, thereby allowing good resolution in dielectric-constant measurement. To make the system self-sustained, the VCO is used as part of a frequency synthesizer system for frequency-to-voltage conversion and digital extraction of the frequency shift using a unique detection algorithm. The dielectric constant of several organic liquids have been extracted to an accuracy better than 2% using sample volumes of 50-200 μL , and has excellent agreement with reported values. The applicability of this system for sensing dielectric mixtures has also been shown, and volume fraction estimation has been demonstrated to an accuracy of around 1%.
机译:在本文中,使用负电阻压控振荡器(VCO)的振荡频率偏移来测量有损耗有机液体的介电常数。详细介绍了振荡器的设计和工作原理以及材料损失的影响。对于介电常数在4.5 GHz时2-13之间的50-200μL有损测试样品体积,所提出的方法可提供10-110 MHz的相对较大的频移,从而在介电常数测量中具有良好的分辨率。为了使系统能够自我维持,VCO用作频率合成器系统的一部分,可使用独特的检测算法进行频率到电压的转换以及对频移的数字提取。使用50-200μL的样品体积,已提取出几种有机液体的介电常数,其精度优于2%,并且与报告值具有极好的一致性。还显示了该系统在感测介电混合物中的适用性,并且体积分数估算已证明约为1%的精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号